Oktul home
  • English
  • Estonian

The documentation is in English only.

Contact us

SCIM API

The SCIM 2.0 requests Oktul eID SSO answers, its bearer token, the identifier attribute and every status code, for an identity admin or a SCIM client.

The app has a SCIM 2.0 server that receives users. Microsoft Entra ID is the client it is built and tested for. Provision users from Entra ID is the setup guide; this page lists what the server answers.

Address and token

  • The address is the Tenant URL on the app’s SCIM tab. It belongs to the installation.
  • Every request carries Authorization: Bearer and the SCIM token. Any other request gets 401.
  • The token is generated on the SCIM tab and shown once. The app stores only a SHA-256 hash of it. Replace SCIM token makes a new one, and the old one stops working at once.

Requests

Request What it does
GET /Users?filter=… Finds a user by userName (in any letter case), externalId or id, with eq
POST /Users Creates a user. 201
GET /Users/<id> Reads a user
PUT /Users/<id> Replaces a user
PATCH /Users/<id> Changes a user, including the forms Entra ID sends
DELETE /Users/<id> Deletes a user. 204
GET /ServiceProviderConfig, /Schemas, /ResourceTypes Discovery
  • GET /Users without a filter answers 400 tooMany. The server lists no users.
  • /Groups answers 404. Turn group provisioning off in the client.
  • Bulk requests, sorting, ETags and password changes are not supported, and /ServiceProviderConfig says so.

The user resource

Attribute Stored Notes
id Yes Made by the server
userName Yes Required. Unique, in any letter case
emails[type eq "work"].value Yes, one address The email Atlassian knows the user by. Unique, in any letter case. Without a work email, an email-shaped userName is used
externalId Yes The permanent ID the app sends to Atlassian. Unique. A user without it cannot log in
active Yes An inactive user cannot log in
urn:ietf:params:scim:schemas:extension:oktul:2.0:User:nationalIdentifier Yes The country and personal code, as PNOEE-38001085718. Unique. Never returned
Every other attribute No Accepted and ignored

The national identifier

  • The form is PNO, the country (EE, LV or LT), a hyphen and the eleven-digit code. Anything else is refused with 400 invalidValue. The message names the rule and never the value.
  • A bare code is refused the same way. The server never assigns a country to digits.
  • It is write-only. The schema marks it returned: "never", and no answer carries it.
  • A PUT that leaves it out keeps the stored one. Only an explicit null or an empty string clears it.

Status codes

Status When
200, 201, 204 The request was done
400 invalidValue A value is missing or malformed, the identifier among them
400 tooMany GET /Users without a filter
401 No valid bearer token
404 No such user, or an unknown resource such as /Groups
405 The method is not supported on that path
409 uniqueness Another user holds that userName, email, externalId or identifier. The message names which
409, without a scimType Other requests changed the same user at the same moment. Send the request again
413 The request body is too large
500 Storage failed. Send the request again

A PUT or PATCH that changes no stored value writes nothing and answers with the user as stored, so its version and lastModified stay as they were.

A SCIM client other than Entra ID

Any SCIM 2.0 client that can send the identifier attribute can use the server. We have tried only Entra ID.

What the server records

  • In the audit log, when you record them: each user created, changed or deleted, and a request with a wrong token, at most once every 10 minutes. Reads are not recorded. See audit log.
  • In its technical log: the method, the kind of path, the status and a fixed reason. Never a user name, an email address, an identifier or the token.

A problem or a question? Write to support@oktul.com or open a request in the Help Center (opens in a new tab).